The Revision Femoral Condyle is a premium orthopedic implant blank engineered specifically for high-demand knee replacement surgeries. Cast from medical-grade cobalt-chromium-molybdenum alloy, this component provides a critical foundation for surgeons to restore joint stability, reduce chronic pain, and recover optimal mobility for patients requiring complex revision procedures.
Utilizing a sophisticated lost-wax casting process, our femoral condyles ensure exceptional dimensional accuracy and structural integrity. By adhering to strict international standards and featuring a precise machining allowance, these artificial joint blanks allow for seamless customization, ensuring a natural postoperative feel and a significant improvement in the patient's overall quality of life.
| Material Composition | Cobalt-Chromium-Molybdenum Alloy | Manufacturing Process | Precision Lost-Wax Casting |
|---|---|---|---|
| Regulatory Standard 1 | YY0117.3-2005 | Regulatory Standard 2 | ISO5832-4 |
| Machining Tolerance | ±0.3mm | Product Appearance | Off-white metallic sheen |
| Application Area | Knee Joint Revision | Biocompatibility | Excellent / Medical Grade |
| Mechanical Properties | High Strength & Wear Resistance | Design Type | Anatomical Femoral Condyle |
Made from Co-Cr-Mo alloy, ensuring minimal immune response and maximum safety for long-term implantation.
High-strength alloy materials provide excellent wear resistance, extending the lifespan of the joint replacement.
The lost-wax technique ensures high dimensional accuracy, reducing the need for extensive post-processing.
Fine-tuned geometry supports a full range of motion for a more natural postoperative movement feel.
A machining allowance of ±0.3mm allows surgeons to customize the implant to the patient's unique anatomy.
Fully compliant with ISO5832-4 and YY0117.3-2005 standards for guaranteed medical safety.
Strict inspection of raw Co-Cr-Mo materials to ensure zero impurities.
Full traceability from lost-wax casting to the final machined blank.
Digital measurement systems to verify the ±0.3mm machining allowance.
Regular auditing against ISO and YY standards for surgical implants.
Specialized medical-grade packaging to prevent contamination during transit.
Continuous improvement of anatomical designs for better patient outcomes.
| Performance Metric | Standard Casting | Our Precision Process |
|---|---|---|
| Dimensional Accuracy | Moderate | Ultra-High (±0.3mm) |
| Material Pureness | Standard Alloy | Certified ISO5832-4 Alloy |
| Surgical Fit Time | Longer Adjustment | Rapid Customization |
| Wear Rate | Standard | Significantly Reduced |
| Patient Recovery | Standard | Optimized Mobility |
Co-Cr-Mo alloy is preferred for artificial joints due to its exceptional mechanical strength, superior wear resistance, and excellent biocompatibility, ensuring the implant lasts longer within the human body.
Lost-wax casting allows for the creation of complex, anatomical shapes with high precision, resulting in a blank that requires less machining and provides a better fit for the patient.
It provides the orthopedic surgeon with a precise amount of extra material, allowing them to fine-tune the implant's dimensions to perfectly match the patient's bone structure during surgery.
Yes, our products are strictly manufactured to comply with ISO5832-4 and YY0117.3-2005 standards, ensuring safety and reliability for medical use.
While specifically designed as a Revision Femoral Condyle for complex cases, the high-quality alloy and precision casting make them suitable for various high-performance knee joint applications.
By providing a more natural anatomical fit and superior durability, it reduces joint friction and pain, helping patients return to their daily activities with improved mobility.
中国
土耳其
印度
俄罗斯
德国
鹿
瑞士
阿根廷
获取定制解决方案!
联系我们为您提供更专业的服务